Bodenhülse aus Rechteckrohr 70 x 50 x 3 mm für Zaunpfosten 60 x 40 mm, feuerverzinkt

Ground Sleeve for Fence Posts 60 x 40 mm - For Setting in Concrete, Hot-Dip Galvanized

Black Weeks bis 30.11.: bis zu 400 € Rabatt ab 500 € Warenwert Stufen
SKU: BH-ZP55

Post can be removed again without chiseling

Sturdy wall thickness of 3 mm

Hot-dip galvanized, durable in the ground

Fits all 60 x 40 mm fence posts from our range

Gesetzliche Gewährleistung (EU-Hinweis) Ihr Europa

Für Gewerbe und Kommunen: Bis 18.12. bestellen – auf Wunsch stellen wir die Rechnung noch 2026. Eine kurze Nachricht an shop@kirchberger-metall.de genügt.

Quantity:
Sale price29,56 €inkl. MwSt.

Parcel or freight item: plus shipping, free shipping within Germany from €1,000 Shipping info

Lieferzeit: 2 to 3 weeks
Spedition/Paketdienst mit Terminankündigung (Avis)
Frage zum Produkt
American Express Apple Pay EPS Google Pay Klarna Mastercard PayPal Satispay Visa Kauf auf Rechnung Vorkasse
5,0 82 Google-Bewertungen

Ground Sleeve for Fence Posts 60 x 40 mm for Setting in Concrete

The sleeve is set in concrete, the post is inserted into it. That sounds like a detour, but there is a solid reason for it: the post can be pulled out again later without anyone breaking open the foundation.

This pays off wherever the fence is not meant to stand forever or where an opening is needed once a year. On club grounds, at an access road for harvesting machinery, at a construction site enclosure. The sleeve is also worth its weight in gold when the installation is rebuilt later, because the foundations can stay in place.

Technical Data

  • Rectangular tube 70 x 50 x 3 mm
  • Length 500 mm
  • For fence posts with a cross section of 60 x 40 mm
  • For setting in concrete
  • Hot-dip galvanized

What to Watch When Setting Them

The sleeve has to stand plumb before the concrete sets. A crooked post cannot be straightened afterwards, because it takes on the direction of the sleeve. Line the sleeves up along a string line and fix them in place until the concrete has cured. The sleeve swallows 500 mm of post length – allow for this when ordering the posts. You will find all fence posts in the overview.

Your Benefits

  • Post can be removed again without breaking open the concrete
  • Substantial wall thickness of 3 mm
  • Hot-dip galvanized, durable in the ground
  • Fits all fence posts 60 x 40 mm from our range

Questions and Answers

Because shipping a single cap as a parcel costs more than the cap itself. Freight does not depend on quantity: one cap and ten caps travel in the same parcel. With a pack you therefore pay the shipping once for an entire side of fencing. About eleven posts are set for roughly 25 meters of fence, so one pack covers almost all of it.

Measure the tube, not the old cap. What matters is the cross section: 60 x 40 mm on the common double-rod mesh fence posts, 60 x 60 mm on corner posts made of square tube, 40 x 40 mm on light posts and 80 x 80 mm on the gate post. Within 60 x 40 mm the version also differs: for the type A fence post there is the cap with an overhang, for types P and U the flush version.

Plastic fades under UV radiation and becomes brittle over the years, whereas aluminum stays color-stable. On a fence behind the house this is barely noticeable; on the street side it is clearly visible after a few years. Aluminum is also available in three shapes: flat, as a cube and with a ball. The flat cap keeps the line calm, while the cube and the ball create a visible finishing detail.

It closes off the top of the post tube. Without a cap, rainwater runs in and stands above the concreted base, because it cannot drain away at the bottom. On a hot-dip galvanized post it takes a long time before anything becomes visible. On a powder-coated post, corrosion works from the inside out and makes the coating flake off at the edge of the tube.

By up to one meter with the insert adapter, without breaking open the foundations. The adapter is inserted into the top of the existing post, and a shortened piece of post goes on top of it. Beyond that, the leverage on the foundation increases so much that the installation needs to be recalculated, because the existing foundation was designed for the original height. That applies all the more if privacy screen strips are to be woven in as well.

The post lacks the reserve for the additional wind load. With strips woven in, the fence is no longer an air-permeable surface: the wind pushes against it instead of passing through. For existing installations there is the universal post reinforcement, which is pushed into the post and absorbs the bending. If you are building new and plan on a privacy screen, choose the privacy screen post with the stronger 80 x 40 x 2 mm tube from the start.